• Induced Draft Type Evaporative Condensing Unit Evaporative Condenser Chiller
  • Induced Draft Type Evaporative Condensing Unit Evaporative Condenser Chiller
  • Induced Draft Type Evaporative Condensing Unit Evaporative Condenser Chiller
Induced Draft Type Evaporative Condensing Unit Evaporative Condenser Chiller

Induced Draft Type Evaporative Condensing Unit Evaporative Condenser Chiller

Product Details:

Place of Origin: Jinan, Shandong, China
Brand Name: Ourfuture
Certification: CE, 3C, ISO9001:2008, 18 patents
Model Number: BNE500

Payment & Shipping Terms:

Minimum Order Quantity: 1 unit
Price: USD 10000 Per Unit
Packaging Details: Plywood case with steel pallet
Delivery Time: 20~30 days
Payment Terms: T/T, L/C, etc.
Supply Ability: 50 units per month
Get Best Price Contact Now

Detail Information

Fan Brand: Ebmpapst, Ziehl-Abegg Refrigerant: R22, R134a, R404a, R407c, R507c, R744, R717
Voltage: 380V/3Phase/50Hz, 220V/3Phase/60Hz Use: Cold Room, Refrigeration, Supermarket, Pharmacy, Meat Produce
Key Components: Danfoss, Siemens, Ebmpapst Compressor Type: Reciprocating Compressor, Screw Compressor, Scroll Compressor
High Light:

evaporative cooling condenser

,

evaporative condenser chiller

Product Description

1,Before selection,you could provide cooling water consumption,influent water temperature,outlet water temperature,air wet bulb temperature.

2,You can run - 50 ℃,The coldest average temperature below -10 ℃, should tell us when you order

it,We will take ice prevention measures.

3,Circulating water turbidity is less than 50 mg/L,Can’t contain oil and impurities.

4,Influent water temperature less than 60 ℃.

5,In and out of the water pipe can be 90 °,180°,270°rotation direction.

6,The fan blade Angle is adjustable,To ensure that the Angle is consistent.

7,No more than the rated current of the motor.

8,pay attention to fire prevention,press resistant.

 

Model Nominal Conditions Heat Exhaustion Coil Internal volume Axial Fan Circulating Pump Weight External Dimension
Fan Qty Model Power Air volume Qty Model Power Flow rate Freight Operation L L1 W H H1 H2
kw L kw m³/h kw m³/h kg kg mm mm mm mm mm mm
BNE-250 250 330.4 2 LQF-7.5 2×1.1 2×17000 1 65LP2-1.1 1.1 36 1930 3200 1920 280 1320 3540 1250 1870
BNE-300 300 377.6 2 LQF-7.5 2×1.1 2×17000 1 65LP2-1.1 1.1 36 2100 3460 2170 280 1320 3540 1250 1870
BNE-350 350 407.3 2 LQF-7.5 2×1.1 2×17000 1 65LP2-1.1 1.1 36 2250 3620 2170 280 1410 3540 1250 1870
BNE-400 400 472.0 2 LQF-8 2×1.5 2×22000 1 80LP2-1.1 1.1 53 2800 3940 2170 320 1320 3770 1250 2100
BNE-450 450 509.1 2 LQF-8 2×1.5 2×22000 1 80LP2-1.1 1.1 53 3000 4070 2170 320 1410 3770 1250 2100
BNE-500 500 583.1 2 LQF-10 2×2.2 2×32000 1 80LP2-1.1 1.1 53 3450 4350 2170 320 1590 3920 1400 2100
BNE-550 550 620.1 2 LQF-10 2×2.2 2×32000 1 80LP2-1.5 1.5 70 3800 4720 2170 320 1680 3920 1400 2100
BNE-600 600 755.3 4 LQF-7.5 4×1.1 4×17000 1 80LP2-1.5 1.5 70 4000 5570 2560 320 2170 3710 1420 1870
BNE-700 700 814.5 4 LQF-7.5 4×1.1 4×17000 1 80LP2-2.2 2.2 84 4490 7070 2740 320 2170 3710 1420 1870
BNE-800 800 944.1 4 LQF-8 4×1.5 4×22000 1 80LP2-2.2 2.2 84 4600 7390 2560 320 2170 3940 1420 2100
BNE-900 900 1018.1 4 LQF-8 4×1.5 4×22000 1 100LP4-2.2 2.2 100 5400 8090 2740 370 2170 3940 1420 2100
BNE-1000 1000 1166.2 4 LQF-10 4×2.2 4×32000 1 100LP4-2.2 2.2 100 5670 9000 3100 370 2170 4190 1670 2100
BNE-1100 1100 1240.3 4 LQF-10 4×2.2 4×32000 1 100LP4-3 3 120 6100 9880 3270 370 2170 4190 1670 2100
BNE-1200 1200 1416.1 6 LQF-8 6×1.5 6×22000 1 100LP4-3 3 120 7560 10400 3800 370 2170 4290 1770 2100
BNE-1350 1350 1527.2 6 LQF-8 6×1.5 6×22000 1 125LP4-3 3 150 7800 11280 4070 410 2170 4290 1770 2100
BNE-1500 1500 1749.4 6 LQF-10 6×2.2 6×32000 1 125LP4-3 3 150 8100 12460 4610 410 2170 4290 1770 2100
BNE-1650 1650 1860.4 6 LQF-10 6×2.2 6×32000 1 125LP4-4 4 180 8780 13300 4870 410 2170 4290 1770 2100
BNE-1800 1800 2036.3 8 LQF-8 8×1.5 8×22000 1 125LP4-4 4 180 8950 14490 5400 410 2170 4360 1990 2100
BNE-2000 2000 2332.5 8 LQF-10 8×2.2 8×32000 2 100LP4-2.2 2×2.2 2×100 11200 16340 6120 370 2170 4360 1990 2100
BNE-2200 2200 2480.6 8 LQF-10 8×2.2 8×32000 2 100LP4-3 2×3 2×120 12000 17810 6460 370 2170 4360 1990 2100
BNE-2500 2500 2915.6 10 LQF-10 10×2.2 10×32000 2 100LP4-3 2×3 2×120 13500 22190 7630 410 2170 4360 1990 2100
BNE-2750 2750 3100.7 10 LQF-10 10×2.2 10×32000 2 125LP4-3 2×3 2×150 14500 24270 8060 410 2170 4360 1990 2100

 

 

Induced Draft Type Evaporative Condensing Unit Evaporative Condenser Chiller  0Induced Draft Type Evaporative Condensing Unit Evaporative Condenser Chiller  1

Want to Know more details about this product
I am interested in Induced Draft Type Evaporative Condensing Unit Evaporative Condenser Chiller could you send me more details such as type, size, quantity, material, etc.
Thanks!