Blast Freezer Screw Water Cooled Chiller System With Oil Separator
Product Details:
Place of Origin: | China |
Brand Name: | Ourfuture |
Certification: | ISO 9001:2008, CE, CCC, QS |
Model Number: | OBL5M-A |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 unit |
---|---|
Price: | nigotiation |
Packaging Details: | Plastic film + Plywood case |
Delivery Time: | 20 days |
Supply Ability: | 100 units per month |
Detail Information |
|||
Compressor Brand: | , Carlyle, Danfoss, Copeland, Bock, Hanbell, Fusheng, Etc. | Cooling Type: | Water Cooled |
---|---|---|---|
Refrigerant: | R404a, R22 | Voltage: | 380V/3P/50Hz, 220V/1P/60Hz |
Use: | Cold Room, Blast Freezer, Cold Chain Logistic, Pharacy, Refrigeration | Evaporating Temperature: | 10~-15℃, -15~-35℃, -30~-50℃ |
Condensing Temperature: | 35℃ | ||
High Light: | water cooled chillers,industrial water chiller units |
Product Description
Blast Freezer Screw Water Cooled Chiller System With Oil Separator
Wide Range of Options
Compressor Unit |
Refrigeration Capacity |
Evaporating temperature |
Piston type single-stage parallel unit |
20HP~350HP |
7.5℃~-45℃ |
Piston type Two-stage parallel unit |
16HP~180HP |
-25℃~-65℃ |
Screw type single stage parallel unit |
80HP~600HP |
5℃~-45℃ |
Screw type double-stage parallel unit |
100HP~600HP |
-30℃~-65℃ |
Adopted to multiple refrigerant R404a, R507, R407C, R22.
Stable & Reliable Performance
The units are equipped with world famous brand high quality compressor and components,
following the latest design, the perfect combination provides a safe and reliable system.
The unit comes standard with a controller that can effectively avoid turning on/off the motor
frequently as well as safety protection modules including the following: Phase loss protector,
Inverted sequence, overvoltage protector, undervoltage protector, oil pressure, high pressure,
low pressure, motor overload.
High efficiency oil separating system. When power is on, there is no need to add lubricating oil,
the standard provided oil heater (for screw unit), oil temperature controller (for screw unit) and
oil level switch (for screw unit), etc. can protect the function.
The PLC controller is a standard provided component. It can automatically decide the compressor
quantity to be used based on actual need of refrigerant capacity, average the running time
between each compressor, save the power. All of these will guarantee an over 30% longer
usage than single compressor condensing unit.
It has a unique low environment condensing pressure monitor system which guarantees a stable
functioning when there is a low ambient temperature, lack of oil feeding or oil flow warnin
High efficiency gas liquid separator is used, with a unique pipeline design, it can effectively
minimize the possibility of liquid strike.
The “Pressure Vessel Certificate” approved reservoir is provided as well as the safety relief valve.
Fault isolation device is served so that when a certain compressor breaks down, the rest of the
unit can keep running appropriately, making sure that client has enough time for repair and
replacement.
High efficiency & energy saving
Because of a huge demand difference between seasons for refrigerating capacity, the unit must
have a high level control for capacity, so that the unit can keep running under high efficiency
mode. The average parallel unit efficiency, according to different refrigeration system is 30%
higher than single compressor unit.
Using multiple compressor parallel units can provide a multiple energy level control, the
refrigeration output can be dynamically allocated more smoothly according to actual situation.
With high efficiency oil separator, only a small amount of lubricating oil enters the system,
this largely brings up the heat exchanging efficiency.
The PLC controller monitors running compressors quantity, it maintains a maximum use rate
even when only parts of the compressors are functioning.
PLC controller can be set with the best running curve (maximum & minimum power comsuption),
to same as much electricity as possible.
With “modularized design” the risk during construction can be largely reduced, construction
period can be shortened, improve the product quality controllability.
Compact & Nimble Structure
Components such as compressor, reservoir, gas-liquid separator, oil separator, economizer,
intake manifold, fluid supply manifold, electrical control equipment are all centralized, making
sure every inch of the space is fully used.
The unit has a compact structure, the space saved during assembly can provide more space for
commercial use, benefiting the end user with extra profit.
Easy operation & convenience
With PLC safety auto control, client can program with touch screen, the graphical control
interface can intently show the running status, recording data, parameter settings and false
alarming, easy for operation.
The reserved remote communication interface can help customer to monitor remotely.
Thanks to the print output interface, customer can print the running history data of the unit and
the system.
Air cooled piston type condensing unit
General Features
Green refrigerant R404a is used.
High efficiency and low noise external rotor fan motor is used.
Box type integrated design, internal built high efficiency coper tube aluminum fin conderser.
PTC sensor is used to monitor motor temperature.
Polyester oil pre-filled.
Single stage condensing unit has been extended from 27 KW to 800 KW (variety of options)
Double stage condensing unit has been extended from 21 KW to 174 KW (variety of options)
Standard condensing unit configuration
Semi hermetic screw type compressor, box type air cooled condenser, secondary oil separator, exhaust
temperature protection device, reservoir (certificated), low temperature area gas-liquid separator,
dashboard, filter, sight glass, frozen oil, oil differential controller, intercooler and air/oil cooled condenser
for low temperature units, air-cooled oil cooler, etc.
Optional configuration
- R134a, R507, R22, etc
- Extra large reservoir,.
- Condenser fan speed controller
Code description
O |
B |
H |
2 |
M- |
A |
Ourfuture Refrigeration |
Condensing unit type: B-Single stage semi hermatic SB-Double stage semi hermatic |
Compressor type: H-Piston type L-Screw type |
Compressor nominal power (HP) |
Evaporating temp. code: M(Medium & high temp.): 0~-10℃ L(Medium temp.):-10~-30℃ J(Low temp.): -30~-65℃ |
Condenser type: W-Water cooled A-Air cooled |